Hansgrohe 12711001 Instruction Manual Page 26

  • Download
  • Add to my manuals
  • Print
  • Page
    / 32
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 25
26
Problem Possible Cause Solution
Insufficient water - Supply pressure inadequate
- Thermostatic cartridge filter dirty
- Showerhead screen washer or filter
gasket dirty
- Check water pressure (If a pump
has been installed check to see if
the pump is working).
- Clean filters
- Clean screen washer or filter
gasket
Crossflow: hot water being forced
into cold water supply, or vice
versa, when mixer is closed
- Check valves dirty or worn - Clean check valves,replace if
necessary
Output temperature does not
correspond with temperature set
- Handle not justified - Justify the handle
Output temperature is erratic - Temperature regulator dirty or
calcified
- Clean temperature thermostatic
cartridge filters
- Replace thermostatic cartridge
Output water is all hot or all cold
-- doesn't mix (new installation)
- Rough valve is cross connected --
hot on right and cold on left
- Remove function block, turn it 180
and reinstall.
Safety stop override button not
operating
- Spring defective
- Button dirty
- Clean spring and/or button,
replace if necessary
Troubleshooting
Maintenance
Inspect the check valves at least once per year.
Replace the check valves if necessary.
Should the volume of water decrease over time,
inspect and clean the filters on the thermostatic
cartridge. After reassembly, set the high
temperature limit stop and justify the handle.
To prolong the life of the themostatic cartridge,
regularly run it through its full range of
temperatures.